Real-time Temperature and Face Mask Alerts, Abnormal Body Temperature Alert, Forehead Temperature Module and 7-inch Touchscreen; Local offline recognition alert supported; Detects faces and measures temperature within 0.2 seconds; Temperature Range: 86° to 113° F; Measurement Deviation ≤ 0.9° F; Measurement Distance: 1 to 6 feet; Temperature Measurement Version PC Software
Vanadium Oxide uncooled sensor measures a target's temperature
Temperature Measurement Range: 86° to 113° F (30° to 45° C); accuracy: 0.1° C; deviation: ± 0.5° C
Recognition Distance: 1 to 6 feet (0.3 to 1.8 m)
Rapid Temperature Measurement Mode: Detects faces and temperatures without recording identities
Authentication Modes Available: Card and temperature, face and temperature, card and face and temperature, etc.
Face Mask Alert: If a face is detected without a mask, the device can deliver an audible voice reminder. At the same time, the authentication or attendance can then be validated.
Mask Enforcement: If a face is detected without a mask, the device can deliver an audible voice reminder. Authentication or attendance can then be invalidated until a mask is detected.
Temperature measurement results can be displayed on the authentication page.
Voice prompts can be triggered when detecting abnormal temperatures.
Door status (open/close) when detecting abnormal temperature can be configured.
Transmits on- and offline temperature information to client software via TCP/IP communication and saves data on the client software.
Face Recognition Duration: Less than 0.2 seconds per user; face recognition accuracy rate: ≥ 99%
Capacities: 6,000 face images, 6,000 cards, and 100,000 events
Recommended Height for Face Recognition: 4.5 to 6.2 feet (1.4 to 1.9 m)
Supports 6 attendance statuses, including check in, check out, break in, break out, overtime in, overtime out
Watchdog design and tamper-alert
Audio prompt for authentication results
NTP, manual time synchronization, and auto synchronization
Connects to external access controller or Wiegand card reader via Wiegand protocol
Connects to secure door control unit via RS-485 protocol to prevent door opening if terminal suffers vandalism
Imports and exports data to the device from the client software
Notes: *Biometric recognition products are not 100% resilient to spoofing. Elevated security requires multiple authentication modes.
*LTS recommends allowing 90 minutes for the device to acclimatize before use in order to get the most accurate temperature readings.